Services and engineering

1. Chesterton ARC Composite Coatings applying group
Chesterton’s ARC coating provides superior performance against erosion, corrosion, abrasion, and chemical attack. Industry faces adverse environmental conditions that attack components and structures and result in compromised plant reliability and safety and lost profits. When cementitious or metallic surfaces are subject to aggressive industrial application environments you can rely on Chesterton’s 100% solids, low VOC protective linings. ARC Metal Composite Systems (MCS) repair, rebuild and protect all types of industrial process equipment and structures from abrasive, corrosive and chemically aggressive environments.
Main repair center is located in Druskininkai

Druskininkų service centrum Drum coatings Pipe repair

2. Engineering solutions
Maintenance Engineering
Condition Monitoring
Maintenance Planning & Scheduling
Maintenance System Implementation (CMMS)
Pipe inspection. Service life & corrosion speed calculations programs.
Creation of P&ID and PFD drawings with Intergraph PID
Creation of ISO pipe inspection drawings
Relation of outsource databases with Intergraph, Autocad, Microstation drawings
Project mining, relations with Primavera and MS Project
Flange integrity solutions and torque calculations

Data managment Data mining and calculation's ISo, P&ID, PFD drawings

3. Process monitoring group: 
  NDT testing (acoustics emission, ultrasonic, chemical, magnetical diagnostics) 
                                                             LDAR / SLDAR monitoring 
Comprehensive approach for total equipment population.
Effective, reliable, and simple to apply
Best available emissions control technology
Documents and monitors results with proprietary tools
Equipment we used for LDAR measurements according EPA Method 21  - ThermoElectron TVA 1000B. 
SLDAR services is done with Flir GF 320 camera
                                                         Steam trap monitoring
Various types of performance assessment equipment can be used as part of a proactive steam trap
maintenance program to significantly reduce energy losses in steam distribution systems. Approximately
20% of the steam leaving a central boiler plant is lost via leaking traps in typical space heating systems
without proactive maintenance programs. Relatively simple equipment of steam trap monitoring and programs can easily cut losses in half. We are able to work with different equipment for steam trap monitoring 

LDAR emission monitoring Steam trap monitoring SLDAR emission monitoring

                                                           Water Reduction Management
Measures current usage then establishes best practices to maximize reduction.
Substantially reduces water consumption.
Documents economic savings, return on investment
Standardization and Inventory Management
Consolidate existing inventory to minimize spares.
Standardization of sealing systems
Improved precision maintenance practices 
Implementation of BAT procedures
Ultrasonic flow measurements BAT recomendation for water managment Best material and solution selection


  Web For Business
Solution: JSC Artogama